Modelo: CA35T
Marca: Brando
Power: Solenoid
Connection Type: Threaded
Structure: Diaphragm
Valve Type: Right Angle
Voltage: AC24V, AC110V, AC220V, DC24V
Media: Air
Port Size: G1-1/4''
Aperture Of Flow Retea: 35mm
Pressure: 0.3~0.8Mpa
Temperature: -5℃ - 55℃
Paquete: cajas, cartones, paletas
productividad: 100000pcs per month
transporte: Ocean,Land,Air
Lugar de origen: Ningbo, China
Apoyo sobre: 100000pcs per month
Certificados : CE.ISO
Hafen: Ningbo,Shanghai,Guangzhou
Tipo de Pago: L/C,T/T,Paypal
Incoterm: FOB,CFR,CIF
Válvula de diafragma del colector de polvo roscado CA35T
La válvula de chorro de pulso de colector de polvo tipo Goyen CA35T juega un papel importante en el colector de polvo de chorro de pulso Systerm. Es la serie de ángulo recto 't'. También tenemos otro tipo de conexión, como el tipo de ángulo recto con el tipo de tuerca de tocador 'DD', el tipo de montaje múltiple 'MM' y el tipo de 'FS' con bridas.
La válvula de extracción de polvo de pulso utiliza el émbolo de acero inoxidable, que son resistentes a la presión y resistentes al desgaste, y tienen una vida útil de millones de veces. Es un "interruptor" de aire comprimido del sistema de extracción de polvo y soplado de la bolsa de pulso de la bolsa de polvo, y recibe señales de pulso para garantizar el rendimiento del colector de polvo. La resistencia está en el rango de establecimiento, lo que garantiza la capacidad de procesamiento y la eficiencia de absorción del colector de polvo.
Datos técnicos de la válvula de pulso del solenoide CA 35T :
Model No. | CA35T |
Port Size | G1-1/4'' |
Nornimal Size |
Φ35mm |
Action Type | Pilot Operated |
Valve Type | Right Angle |
Number of Diaphrgam | 1 |
TEMP Range |
-5℃ - 55℃ |
Pressure | 0.3~0.8Mpa |
Seal Material | NBR (common) , all available |
Body Material | Aluminum ADC12 |
Deconstrucción de la válvula de pulso electromagnético CA35T :
Part Name | Material |
Solenoid Coil | Copper Wire |
Armature Assembly | Stainless Steel |
Spring | Stainless Steel |
Seals & Diaphragm | NBR (common), all available |
Body | Die-casting Aluminum Alloy |
1. Válvula fugas o no se cierra rápidamente
phenomenon |
Reason |
Solution |
Solenoid Coil Hot |
Solenoid Coil Hot |
Measure whether the coil is energized normally. Check the pulse signal control system to correct incorrect connections |
No power to the coil |
1. Diaphragm rupture 2. The diaphragm surface is dirty and cannot be sealed 3. Hole in blowpipe (submerged) |
1. Repalce Diaphragm 2. Clean diaphragm surface 3. Repair or replace blowpipe |
Broken spring, broken diaphragm |
1.Insufficient air supply after spraying, valve cannot be closed quickly 2.Plunger crooked, diaphragm does not reset properly 3.The coil is energized for a long time, which produces electromagnetic memory |
1. Connect small air bags into a large capacity; Thickened pipe 2. repalce plunger 3. Detect pulse input , repalce solenoid coil |
phenomenon |
Reason |
Solution |
Solenoid coil does not work |
1. Voltage mismatch 2. The solenoid is not powered or burned 3. Plunger Crooked 4. Spring misalignment is stuck |
1. Check if the voltage matches; Replace the pulse control system 2. Repalce solenoid coil 3. Repalace plunger 4. Replace component or reinstall small spring in plunger |
solenoid coil working, but Valve does not blow |
air hole blocked |
Installation cleaning filter |
PRODUCTOS POR GRUPO : Válvula de pulso del colector de polvo > Válvula de chorro de pulso