Válvula de diafragma del colector de polvo roscado CA35T

$22 - 28 /Bag/Bags
  • Descripción
Overview
Atributos del producto

ModeloCA35T

MarcaBrando

PowerSolenoid

Connection TypeThreaded

StructureDiaphragm

Valve TypeRight Angle

VoltageAC24V, AC110V, AC220V, DC24V

MediaAir

Port SizeG1-1/4''

Aperture Of Flow Retea35mm

Pressure0.3~0.8Mpa

Temperature-5℃ - 55℃

Capacidad de suministro e información a...

Paquetecajas, cartones, paletas

productividad100000pcs per month

transporteOcean,Land,Air

Lugar de origenNingbo, China

Apoyo sobre100000pcs per month

Certificados CE.ISO

HafenNingbo,Shanghai,Guangzhou

Tipo de PagoL/C,T/T,Paypal

IncotermFOB,CFR,CIF

Embalaje y entrega
Unidades de venta:
Bag/Bags
Tipo de paquete:
cajas, cartones, paletas

Válvula de diafragma del colector de polvo roscado CA35T

La válvula de chorro de pulso de colector de polvo tipo Goyen CA35T juega un papel importante en el colector de polvo de chorro de pulso Systerm. Es la serie de ángulo recto 't'. También tenemos otro tipo de conexión, como el tipo de ángulo recto con el tipo de tuerca de tocador 'DD', el tipo de montaje múltiple 'MM' y el tipo de 'FS' con bridas.

La válvula de extracción de polvo de pulso utiliza el émbolo de acero inoxidable, que son resistentes a la presión y resistentes al desgaste, y tienen una vida útil de millones de veces. Es un "interruptor" de aire comprimido del sistema de extracción de polvo y soplado de la bolsa de pulso de la bolsa de polvo, y recibe señales de pulso para garantizar el rendimiento del colector de polvo. La resistencia está en el rango de establecimiento, lo que garantiza la capacidad de procesamiento y la eficiencia de absorción del colector de polvo.


Datos técnicos de la válvula de pulso del solenoide CA 35T :

Model No. CA35T
Port Size G1-1/4''
Nornimal Size Φ35mm
Action Type  Pilot Operated
Valve Type  Right Angle 
Number of Diaphrgam  1
TEMP Range -5℃ - 55℃ 
Pressure 0.3~0.8Mpa
Seal Material  NBR (common) , all available
Body Material  Aluminum ADC12

Dimensión general de la válvula de pulso solenoide de tipo de ángulo ht de rig rig CA35T:

Overall Dimension of CA35T Right Angle Type Solenoid Pulse Valve:


Deconstrucción de la válvula de pulso electromagnético CA35T :

Deconstruction of CA35T Electromagnetic Pulse Valve:

Part Name  Material 
Solenoid Coil  Copper Wire
Armature Assembly Stainless Steel 
Spring  Stainless Steel 
Seals & Diaphragm  NBR (common), all available
Body  Die-casting Aluminum Alloy 

GOYEN TIPO DE VÁLVULA DE PULSO SOLENOIDO Preguntas frecuentes :

1. Válvula fugas o no se cierra rápidamente

phenomenon
Reason Solution
Solenoid Coil Hot
Solenoid Coil Hot
Measure whether the coil is energized normally. Check the pulse signal control system to correct incorrect connections
No power to the coil 
1. Diaphragm rupture  
2. The diaphragm surface is dirty and cannot be sealed
3. Hole in blowpipe (submerged)
1. Repalce Diaphragm
2. Clean diaphragm surface
3. Repair or replace blowpipe 
Broken spring, broken diaphragm 
1.Insufficient air supply after spraying, valve cannot be closed quickly
2.Plunger crooked, diaphragm does not reset properly
3.The coil is energized for a long time, which produces electromagnetic memory
1. Connect small air bags into a large capacity; Thickened pipe
2. repalce plunger
3. Detect pulse input , repalce solenoid coil 

2. La válvula no se puede abrir después de ser energizado

phenomenon
Reason
Solution
Solenoid coil does not work
1. Voltage mismatch
2. The solenoid is not powered or burned
3. Plunger Crooked
4. Spring misalignment is stuck
1. Check if the voltage matches; Replace the pulse control system
2. Repalce solenoid coil 
3. Repalace plunger
4. Replace component or reinstall small spring in plunger
solenoid coil working, but Valve does not blow
air hole blocked
Installation cleaning filter

¡Bienvenido a su pregunta y consulta!

PRODUCTOS POR GRUPO : Válvula de pulso del colector de polvo > Válvula de chorro de pulso

Home > Lista de Productos > Válvula de pulso del colector de polvo > Válvula de chorro de pulso > Válvula de diafragma del colector de polvo roscado CA35T
Contactar proveedor
  • *Asunto:
  • *A:
    Mr. Brandon Bao
  • *Móvil:
  • *Email:
  • *Mensaje:
    Su mensaje debe ser de entre 20 a 8,000 caracteres.
Realizar consulta
*
*
*

Inicio

Product

Phone

Sobre Nosotros

Solicitar

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Enviar